About 163,000 results
Open links in new tab
  1. 2 Romex's in one connector | Information by Electrical Professionals ...

    Jan 28, 2012 · Which romex connector? It sounds like a good possibility of you being wrong...typically you can fit 2 12/2 or 14/2 through one nm, romex clamp connector, but without knowing the exact …

  2. romex wires into a service panel | Information by Electrical ...

    Sep 15, 2003 · Re: romex wires into a service panel Get you a couple of 2" plastic ko bushings, ko two 2" holes in your panel and job done, they work great in such an installation and inspectors have …

  3. Romex Connectors installed from the inside of the box

    Jul 23, 2007 · Does anyone know of a romex connector that can be installed from the inside of an EXISTING junction box. I can't access the outside of the box without opening up the drywall, and the …

  4. "Romex Connectors" | Information by Electrical Professionals for ...

    Aug 20, 2003 · Re: "Romex Connectors" Unless identified on the carton ( for two screw connectors ) for more than one cable per connector, one cable per connector is the maximum. No sure which year, …

  5. How many wire per hole through studs | Information by Electrical ...

    Jan 2, 2020 · I have been told my whole career that you can only run two romex through a hole in a stud. You are allowed to run as many wires as you want through a nipple, under 18" without derating …

  6. Installing romex in EMT conduit | Information by Electrical ...

    Sep 20, 2022 · I also recently passed romex through a double gang metallic box without breaking wires out of jacket, straight in left to exit rear. Code requires equipment to be bonded if likely to be …

  7. romex clamps | Information by Electrical Professionals for Electrical ...

    Mar 18, 2008 · is there a code section that limits the amount of romex cables allowed per clamp? Not specifically. The best you'll do with the NEC is 110.3(B). If the clamp is only listed for one cable that's …

  8. How Connect NM to Panel? - Old Work | Information by Electrical ...

    Aug 17, 2010 · Attach connector to cable, then push back through KO. Or even a metal romex connector if you're coming in through the top of the panel, you can sneak the locknut along the top of the panel …

  9. NM-B plastic connector installation into a panel

    Dec 22, 2021 · Can a NM-B push-in connector be installed from the inside of a panel box on a 2 wire NM-B wire? The wire would be fished thru an existing wood studded sheetrock wall into the panel …

  10. How many 12/2 cables… | Information by Electrical Professionals for ...

    Nov 12, 2022 · How many 12/2 NM cables can you run through a 2 inch Romex connector? I always ran two per 1/2” KO but recently had a few scenarios with a recessed load center and old wires that were …